Electromagnetic Wave


The electromagnetic field can be viewed as the combination of an electric field and a magnetic field. The electric field is produced by stationary charges, and the magnetic field by moving charges (currents); these two are often described as the sources of the field. The way in which charges and currents interact with the electromagnetic field is described by Maxwell's equations and the Lorentz force law.It is further classified as near field and far field.
The near field and far field and the transition zone are regions of time-varying electromagnetic field around any object that serves as a source for the field. The different terms for these regions describe the way characteristics of an electromagnetic (EM) field change with distance from the charges and currents in the object that are the sources of the changing EM field. The more distant parts of the far-field are identified with classical electromagnetic radiation.

The basic reason an EM field changes in character with distance from its source is that Maxwell's equations prescribe different behaviors for each of the two source-terms of electric fields and also the two source-terms for magnetic fields. Electric fields produced by charge distributions have a different character than those produced by changing magnetic fields. Similarly, Maxwell's equations show a differing behavior for the magnetic fields produced by electric currents, versus magnetic fields produced by changing electric fields. For these reasons, in the region very close to currents and charge-separations, the EM field is dominated by electric and magnetic components produced directly by currents and charge-separations, and these effects together produce the EM "near field." However, at distances far from charge-separations and currents, the EM field becomes dominated by the electric and magnetic fields indirectly produced by the change in the other type of field, and thus the EM field is no longer affected (or much affected) by the charges and currents at the EM source. This more distant part of the EM field is the "radiative" field or "far-field," and it is the familiar type of electromagnetic radiation seen in "free space," far from any EM field sources (origins).

The far-field thus includes radio waves and microwaves several wavelengths from most types of antennas etc.



Schumann resonance




Lightning discharges are considered to be the primary natural source of Schumann resonance excitation; lightning channels (e.g clouds) behave like huge antennas that radiate electromagnetic energy at frequencies below 100 hz.These signals are very weak at large distances from the lightning source, but the Earthionosphere waveguide behaves like a resonator at ELF frequencies and amplifies the spectral signals from lightning at the resonance frequency.

Waveguide:

Waves in open space propagate in all directions, as spherical waves. In this way they lose their power proportionally to the square of the distance; that is, at a distance R from the source, the power is the source power divided by R2. The waveguide confines the wave to propagation in one dimension, so that (under ideal conditions) the wave loses no power while propagating.Conductors used in waveguides have small skin depth and hence large surface resistance.
Waves are confined inside the waveguide due to total reflection from the waveguide wall, so that the propagation inside the waveguide can be described approximately as a "zigzag" between the walls. This description is exact for electromagnetic waves in a hollow metal tube with a rectangular or circular cross-section. 
The real Earthionosphere waveguide is not a perfect electromagnetic resonant cavity.

Cavity resonators:

A cavity resonator is a hollow conductor blocked at both ends and along which an electromagnetic wave can be supported. It can be viewed as a waveguide short-circuited at both ends .
The cavity's interior surfaces reflect a wave of a specific frequency. When a wave that is resonant with the cavity enters, it bounces back and forth within the cavity, with low loss (due to standing waves which are formed due to interaction of waves with different velocities). As more wave energy enters the cavity, it combines with and reinforces the standing wave, increasing its intensity.
Losses due to finite ionosphere electrical conductivity lower the propagation speed of electromagnetic signals in the cavity, resulting in a resonance frequency that is lower than would be expected in an ideal case, and the observed peaks are wide (rather sharp).In addition, there are a number of horizontal asymmetries day-night difference in the height of the ionosphere, latitudinal changes in the Earth magnetic field, sudden ionospheric disturbances, polar cap absorption, variation in the Earth radius of +/- 11 km from equator to geographic poles, etc. that produce other effects in the Schumann resonance power specification.


Schumann resonances are recorded at many separate research stations around the world. The sensors used to measure Schumann resonances typically consist of two horizontal magnetic inductive coils for measuring the north-south and east-west components of the magnetic field, and a vertical electric dipole antenna for measuring the vertical component of the electric field. A typical passband of the instruments is 3100 Hz. The Schumann resonance electric field amplitude (~300 microvolts per meter) is much smaller than the static fair-weather electric field (~150 V/m) in the atmosphere. Similarly, the amplitude of the Schumann resonance magnetic field (~1 picotesla) is many orders of magnitude smaller than the Earth magnetic field (~3050 microteslas. Specialized receivers and antennas are needed to detect and record Schumann resonances. 

CCD Vs CMOS sensors





Digital cameras have become extremely common as the prices have come down. One of the drivers behind the falling prices has been the introduction of CMOS image sensors. CMOS sensors are much less expensive to manufacture than CCD sensors. 
Both CCD (charge-coupled device) and CMOS (complementary metal-oxide semiconductor) image sensors start at the same point -- they have to convert light into electrons. One simplified way to think about the sensor used in a digital camera (or camcorder) is to think of it as having a 2-D array of thousands or millions of tiny solar cells, each of which transforms the light from one small portion of the image into electrons. Both CCD and CMOS devices perform this task using a variety of technologies. 
In a CCD device, the charge is actually transported across the chip and read at one corner of the array. An analog-to-digital converter turns each pixel's value into a digital value. In most CMOS devices, there are several transistors at each pixel that amplify and move the charge using more traditional wires. The CMOS approach is more flexible because each pixel can be read individually. 
CCDs use a special manufacturing process to create the ability to transport charge across the chip without distortion. This process leads to very high-quality sensors in terms of fidelity and light sensitivity. CMOS chips, on the other hand, use traditional manufacturing processes to create the chip -- the same processes used to make most microprocessors. Because of the manufacturing differences, there have been some noticeable differences between CCD and CMOS sensors.
CCD sensors, as mentioned above, create high-quality, low-noise images. CMOS sensors, traditionally, are more susceptible to noise.
Because each pixel on a CMOS sensor has several transistors located next to it, the light sensitivity of a CMOS chip tends to be lower. Many of the photons hitting the chip hit the transistors instead of the photodiode.
CMOS traditionally consumes little power. Implementing a sensor in CMOS yields a low-power sensor.
CCDs use a process that consumes lots of power. CCDs consume as much as 100 times more power than an equivalent CMOS sensor.
CMOS chips can be fabricated on just about any standard silicon production line, so they tend to be extremely inexpensive compared to CCD sensors.
CCD sensors have been mass produced for a longer period of time, so they are more mature. They tend to have higher quality and more pixels.
CMOS sensors are just now improving to the point where they reach near parity with CCD devices in some applications. CMOS cameras are usually less expensive and have great battery life.


Pyroelectricity




Pyroelectricity is the ability of certain materials to generate a temporary voltage when they are heated or cooled.The change in temperature modifies the positions of the atoms slightly within the crystal structure, such that the polarization of the material changes. This polarization change gives rise to a voltage across the crystal. If the temperature stays constant at its new value, the pyroelectric voltage gradually disappears due to leakage current (the leakage can be due to electrons moving through the crystal, ions moving through the air, current leaking through a voltmeter attached across the crystal, etc.).

Pyroelectricity should not be confused with thermoelectricity: In a typical demonstration of pyroelectricity, the whole crystal is changed from one temperature to another, and the result is a temporary voltage across the crystal. In a typical demonstration of thermoelectricity, one side of the material is kept at one temperature and the other side at a different temperature, and the result is a permanent voltage across the crystal.

Pyroelectricity can be visualized as one side of a triangle, where each corner represents energy states in the crystal: kinetic, electrical and thermal energy. The side between electrical and thermal corners represents the pyroelectric effect and produces no kinetic energy. The side between kinetic and electrical corners represents the piezoelectric effect and produces no heat.

Although artificial pyroelectric materials have been engineered,effect was first discovered in minerals such as tourmaline. The pyroelectric effect is also present in both bone and tendon.

Pyroelectric charge in minerals develops on the opposite faces of asymmetric crystals. The direction in which the propagation of the charge tends toward is usually constant throughout a pyroelectric material, but in some materials this direction can be changed by a nearby electric field. These materials are said to exhibit ferroelectricity. All pyroelectric materials are also piezoelectric, the two properties being closely related. However, note that some piezoelectric materials have a crystal symmetry that does not allow pyroelectricity.

Very small changes in temperature can produce an electric potential due to a materials' pyroelectricity. Passive infrared sensors are often designed around pyroelectric materials, as the heat of a human or animal from several feet away is enough to generate a difference in charge.
The pyroelectric coefficient may be described as the change in the spontaneous polarization vector with temperature.The total pyroelectric coefficient measured at constant stress is the sum of the pyroelectric coefficients at constant strain (primary pyroelectric effect) and the piezoelectric contribution from thermal expansion (secondary pyroelectric effect). Thermal expansion is due to heating and cooling.

Artificial pyroelectric materials, usually in the form of a thin film, are of gallium nitride (GaN), caesium nitrate (CsNO3), polyvinyl fluorides, derivatives of phenylpyridine, and cobalt phthalocyanine.


LED





The LED consists of a chip of semiconducting material doped with impurities to create a p-n junction. As in other diodes, current flows easily from the p-side, or anode, to the n-side, or cathode, but not in the reverse direction. Charge-carriers—electrons and holes—flow into the junction from electrodes with different voltages.
When a light-emitting diode is switched on, electrons are able to recombine with holes within the device, releasing energy in the form of photons. This effect is called electroluminescence and the color of the light (corresponding to the energy of the photon) is determined by the energy band gap of the semiconductor.
The wavelength of the light emitted, and thus its color depends on the band gap energy of the materials forming the p-n junction. In silicon or germanium diodes, the electrons and holes recombine by a non-radiative transition, which produces no optical emission, because these are indirect band gap materials. The materials used for the LED have a direct band gap with energies corresponding to near-infrared, visible, or near-ultraviolet light. LED development began with infrared and red devices made with gallium arsenide.




















































In semiconductor physics, the band gap of a semiconductor is always one of two types, a direct band gap or
an indirect band gap. The band gap is called "direct" if the momentum of electrons and holes is the same in both the conduction band and the valence band; an electron can directly emit a photon. In an "indirect" gap, a photon cannot be emitted because the electron must pass through an intermediate state and transfer momentum to the crystal lattice. The minimal-energy state in the conduction band and the maximal-energy state in the valence band are each characterized by a certain crystal momentum  (k-vector) in the Brillouin zone. If the k-vectors are the same, it is called a "direct gap". If they are different, it is called an "indirect gap".
In case of LED display (not to be confused with LED backlid LCD display) cluster of red, green, and blue diodes is driven together to form a full-color pixel, usually square in shape. These pixels are spaced evenly apart and are measured from center to center for absolute pixel resolution.

Tesla Coil






The Tesla coil is one of Nikola Tesla's most famous inventions. It is essentially a high-frequency air-core transformer. It takes the output from a 120v AC to several kilovolt transformer & driver circuit and steps it up to an extremely high voltage. Voltages can get to be well above 1,000,000 volts and are discharged in the form of electrical arcs. Tesla himself got arcs up to 100,000,000 volts. Tesla coils are unique in the fact that they create extremely powerful electrical fields. Large coils have been known to wirelessly light up florescent lights up to 50 feet away, and because of the fact that it is an electric field that goes directly into the light and doesn't use the electrodes, even burned-out florescent lights will glow.

A Tesla coil transformer operates in a significantly different fashion from a conventional (i.e., iron core) transformer. In a conventional transformer, the windings are very tightly coupled and voltage gain is determined by the ratio of the numbers of turns in the windings. This works well at normal voltages but, at high voltages, the insulation between the two sets of windings is easily broken down and this prevents iron cored transformers from running at extremely high voltages without damage.





Unlike those of a conventional transformer (which may couple 97%+ of the fields between windings), a Tesla coil's windings are "loosely" coupled, with a large air gap, and thus the primary and secondary typically share only 1020% of their respective magnetic fields. Instead of a tight coupling, the coil transfers energy (via loose coupling) from one oscillating resonant circuit (the primary) to the other (the secondary) over a number of RF cycles.
In each circuit, the AC supply transformer charges the tank capacitor until its voltage is sufficient to break down the spark gap. The gap suddenly fires, allowing the charged tank capacitor to discharge into the primary winding.

When the spark gap fires, the charged capacitor discharges into the primary winding, causing the primary circuit to oscillate. The oscillating primary current creates a magnetic field that couples to the secondary winding, transferring energy into the secondary side of the transformer and causing it to oscillate with the toroid capacitance. The energy transfer occurs over a number of cycles, and most of the energy that was originally in the primary side is transferred into the secondary side. The greater the magnetic coupling between windings, the shorter the time required to complete the energy transfer. As the primary energy transfers to the secondary, the secondary's output voltage increases until all of the available primary energy has been transferred to the secondary (less losses). Even with significant spark gap losses, a well designed Tesla coil can transfer over 85% of the energy initially stored in the primary capacitor to the secondary circuit.
As the secondary coil's energy (and output voltage) continue to increase, larger pulses of displacement current further ionize and heat the air at the point of initial breakdown. This forms a very conductive "root" of hotter plasma, called a leader, that projects outward from the toroid. The plasma within the leader is considerably hotter than a corona discharge, and is considerably more conductive. In fact, it has properties that are similar to an electric arc. The leader tapers and branches into thousands of thinner, cooler, hairlike discharges (called streamers). The streamers look like a bluish 'haze' at the ends of the more luminous leaders, and transfer charge between the leaders and toroid to nearby space charge regions. The displacement currents from countless streamers all feed into the leader, helping to keep it hot and electrically conductive. 

Armature Reaction

Armature reaction is the reaction or intereaction between the magnetic field produced by the flowing of current in the coil wound on the armature and the main magnetic field of the D.C. genarator or the motor.

The conversion of mechanical energy to the electrical energy in the electric dc motor or generator is due to this interaction.

Armature reaction causes the neutral plane, a plane parallel to armature windings with the magnetic flux, to shift in the direction of rotation. Thus armature reaction distort the magnetic flux (cross magnetisation) and lead the applied field not radial and reduction in magnetic field (de magnetisation ) which changes the efficiency of the output of the dc generator or dc motor.

In order to minimise the armature reaction, two simple methods can be taken up :

1. Shifting of the position of the brushes such that its plane are in the neutral plane (but this is not feasible as single machine is used as both generator and motor).

The brushes of a generator must be set in the neutral plane; that is, they must contact segments of the commutator that are connected to armature coils having no induced emf. If the brushes were contacting commutator segments outside the neutral plane, they would short-circuit "live" coils and cause arcing and loss of power.

2. Installation of interpoles in the generator or motor to nullify the effect of armature reaction although it reduces available flux.
Compensating windings or intrrpoles are used for this purpose.Their function is to neutralize the cross magnetizing effect of armature reaction. The compensating windings consist of a series of coils embedded in slots in the pole faces. These coils are connected in series with the armature in such a way that the current in them flows in opposite direction to that flowing in armature conductors directly below the pole shoes.
The series-connected compensating windings produce a magnetic field, which varies directly with armature current. Because the compensating windings are wound to produce a field that opposes the magnetic field of the armature, they tend to cancel the effects of the armature magnetic field

Armature reaction is response generated by armature of motor or generator to the change in the flux linked with it.This is the main cause for back emf in motors.
The armature reaction generates eddy currents in the armature which may result in losses in the machine.

FAQs of Battery




The amount of charge provided by battery is its capacity. Since charge is the product of current and time , therefore in order to increase capacity , current should be increased. This is done by connecting more number of batteries in parallel. This will provide more charge at same terminal voltage, hence capacity increases.
A household deep cycle  12V  (12.6V on fully charged) battery generally contains six 2V batteries in series  internally.
Each cell performs electrolysis  It has two electrodes , of lead oxide and other of lead. The electrolyte is a mixture of water and sulphuric acid.




                   FULLY CHARGED                                                                









                FULLY DISCHARGED


During complete charging, full amount of sulphuric acid is left as electrolyte along water. With the help of this electrolyte , movement of charge takes place between anode and cathode. As discharging begans, the sulphuric acid starts accumulating over electrodes and at complete discharge only water is left as electrolyte. Thus transfer of charge stops and we say that battery is down.
During these processes , some unwanted phenomenon also takes place which are as follows:

Sulphonation:

During charging there should complete transfer of sulphate from electrodes to electrolyte but it is not practacally observed. Some amount of sulphate remains on electrodes . This is sulphonation. It reduces the cross section area of plate and hences reduces capacity. To avoid this , desulphonation process is performed to remove layers of sulphates from electrodes.

Stratification :

Since water and sulphuric acid both are present in electrolyte  and water is lighter. lighter therefore after some time sulphuric acid settles down. Due to this, corrosion takes place in the lower section of electrodes. To avoid this, it is advised to discharge completely the battery after long cycles or if possible shake the battery frequently.

Explosion:

Due to over chaging , electrolysis of water takes place and hydrogen gas is formed. Since it is a supporter of cumbustion and temperature is also high it explodes.
To avoid this , some ventillations are provided.
        

Aurora





Aurora  is a natural light display in the sky particularly in the high latitude (Arctic and Antarctic) regions, caused by the collision of energetic charged particles with atoms in the high altitude atmosphere (thermosphere). The charged particles originate in the magnetosphere and solar wind and, on Earth, are directed by the Earth's magnetic field into the atmosphere. Most aurorae occur in a band known as the auroral zone

It is basically an electrical phenomenon.

Auroras result from emissions of photons in the Earth's upper atmosphere, above 80 km (50 mi), from ionized nitrogen atoms regaining an electron, and oxygen and nitrogen atoms returning from an excited state to ground state.  They are ionized or excited by the collision of solar wind (it is basically a photon wave. Photon wave consistes of electrons and protons with high energy.) and magnetospheric particles (this includes charged ions of enviornmental gasses) :The Earth's magnetic field traps these particles, many of which travel toward the poles (since poles have strongest magnetic field) where they are accelerated toward Earth. Collisions between these ions and atmospheric atoms and molecules cause energy releases in the form of auroras appearing in large circles around the poles. Auroras are more frequent and brighter during the intense phase of the solar cycle (i.e. during solar storms) when coronal mass ejections increase the intensity of the solar wind.

Typically the aurora appears either as a diffuse glow or as "curtains" that approximately extend in the east-west direction. At some times, they form "quiet arcs"; at others ("active aurora"), they evolve and change constantly. Each curtain consists of many parallel rays, each lined up with the local direction of the magnetic field lines, suggesting that auroras are shaped by Earth's magnetic field. Indeed, satellites show that electrons are guided by magnetic field lines, spiraling around them while moving toward Earth.
It is observed that large electric currents were associated with the aurora and such currents  flowing from the dayside toward (approximately) midnight were later named "auroral electrojets". 

The colour of aurora is due to following reasons:

Oxygen emissions green or brownish-red, depending on the amount of energy absorbed. nitrogen emissions blue or red; blue if the atom regains an electron after it has been ionized, red if returning to ground state from an excited state. Oxygen is unusual in terms of its return to ground state: it can take three quarters of a second to emit green light and up to two minutes to emit red. Collisions with other atoms or molecules absorb the excitation energy and prevent emission. Because the very top of the atmosphere has a higher percentage of oxygen and is sparsely distributed such collisions are rare enough to allow time for oxygen to emit red. 

Load Shedding


Load shedding is what electric utilities do when there is a huge demand for electricity that exceeds the generation available. The alternative is to have a brown-out where the voltage is reduced. 

It costs a lot to have generators standing by just in case there is a surge of demand, and the operators of those generators expect to be paid whether they run the generators or not. An alternative is if there is a large consumer of electricity (say, a factory) that could suddenly turn off all its electricity demand, they could agree to do that on request, and it has the same benefit as adding that amount of generation to the electric grid. In fact, it's better -- as there is less demand on the wires which are often saturated at the same time. 

That factory has losses from shutting down its equipment and idling its workers, but if the money it gets paid is enough, then it's worth it. This is an example of load shedding. 

There are many other cases where lots of smaller consumers agree to reduce demand on hot summer days, such as by reducing air conditioning or lighting. 

Someone who aggregates all these smaller cases can have the same effect as one big generator and so get the same money, and the operators of the electric grid are happy as it effectively solves the peak demand problem. 

When there is a shortfall in the electricity supply, there can be a need to reduce demand very quickly to an acceptable level, or risk the entire electricity network becoming unstable and shutting down completely. This is known as a “cascade” event, and can end in a total or widespread network shutdown affecting very large areas of a country. Some recent examples include the blackouts in northeast America and Canada in 2003 and across Italy in the same year and in India in 2012.

As the system frequency approaches the normal 60 Hz or 50 Hz ,a frequency relay can be used to automatically begin the restoration of the load that has been shed. The amount of load that can be restored  is determined by  the ability of the system to serve it .The criteria is that   the available generation must  always exceed  the amount  of  load being restored so that the system frequency will continue to recover . Any serious decrease in system frequency at this point could lead to undesirable load shedding repetition, which could start a system oscillation between shedding and restoration. This would be a highly undesirable condition. The availability of generation, either locally or through system interconnections ,   determines whether or not the shed load can be successfully restored.
Therefore, a load restoration program usually incorporates time delay, which is related to the amount of time required to add generation or to close tie- lines during emergency conditions. Also, both the time delay and the restoration frequency set points should be staggered so that all of the load is not   reconnected at the same time.  Reconnecting loads on a distributed basis also minimizes power swings across the system and thereby minimizes the possibility of initiating a new disturbance.

The drop in frequency may endanger generation itself .While a hydro-electric plant is   relatively unaffected by even a  ten percent  reduction in frequency, a thermal generating plant is quite sensitive  to even a five percent reduction.  Power output of a thermal plant depends to a great extent  on  its motor driven auxiliaries such as boiler feed water pumps, coal pulverizing and feeding equipment, and draft fans. As system frequency decreases, the power output to the auxiliaries begins to fall off rapidly which in
turn further reduces the energy input to the turbine generator. The situation thus has a cascading effect with a  loss of frequency leading to a loss of power which can cause the frequency to deteriorate further and the entire plant is soon in serious trouble. An additional major concern is the possible damage to the steam  turbines due  to prolonged operation at reduced frequency during this severe overload
condition .

Load shedding normally happens in two ways:

Automatic Load Shedding

This is a result of concurrent failures of major element(s) in the national grid (e.g.co-incidental generator or key transmission line failures), resulting in protection schemes initiating the automatic isolation of additional parts of the national grid, to protect the entire grid from cascading to a total blackout. Automatic load shedding always occurs on the transmission system level, with the result being large
amounts of electricity and large blocks of customers taken off supply in a very short time. Typical load reduction amounts can be in the order of 1000MW – 2000MW, affecting hundreds of thousands of customers.

Manual (Selective) Load Shedding

This occurs where time is available (typically up to 30mins) to make selective choices on what customers are shed. Selective load shedding often occurs on the distribution system level, and typically requires medium to small amounts of electricity to be “shed” in a short time (rolling blackout). Typical load reduction amounts can be in the order of 50MW – 100MW, affecting tens of thousands of customers at a time. 

In order to minimise the impact on individual customers and share the burden, rotational load shedding (rolling blckout) will occur on the low priority feeders if the load shedding duration extends for several hours. Typically the first group of customers who were shed will be restored after one or two hours, at the expense of the next group of customers to be taken off supply. This can continue until the supply/demand equation is balanced again and load shedding is no longer required.







Magnetic Inrush



When a transformer is initially connected to a source of AC voltage, there may be a substantial surge of current through the primary winding called inrush current.





We know that the rate of change of instantaneous flux in a transformer core is proportional to the instantaneous voltage drop across the primary winding. Or, as stated before, the voltage waveform is the derivative of the flux waveform, and the flux waveform is the integral of the voltage waveform. In a continuously-operating transformer, these two waveforms are phase-shifted by 90o. Since flux (Φ) is proportional to the magnetomotive force (mmf) in the core, and the mmf is proportional to winding current, the current waveform will be in-phase with the flux waveform, and both will be lagging the voltage waveform by 90o 






Let us suppose that the primary winding of a transformer is suddenly connected to an AC voltage source at the exact moment in time when the instantaneous voltage is at its positive peak value. In order for the transformer to create an opposing voltage drop to balance against this applied source voltage, a magnetic flux of rapidly increasing value must be generated. The result is that winding current increases rapidly, but actually no more rapidly than under normal conditions. Both core flux and coil current start from zero and build up to the same peak values experienced during continuous operation. Thus, there is no "surge" or "inrush" or current in this scenario.





Alternatively, let us consider what happens if the transformer's connection to the AC voltage source occurs at the exact moment in time when the instantaneous voltage is at zero. During continuous operation (when the transformer has been powered for quite some time), this is the point in time where both flux and winding current are at their negative peaks, experiencing zero rate-of-change (dΦ/dt = 0 and di/dt = 0). As the voltage builds to its positive peak, the flux and current waveforms build to their maximum positive rates-of-change, and on upward to their positive peaks as the voltage descends to a level of zero.

In an ideal transformer, the magnetizing current would rise to approximately twice its normal peak value as well, generating the necessary mmf to create this higher-than-normal flux. However, most transformers aren't designed with enough of a margin between normal flux peaks and the saturation limits to avoid saturating in a condition like this, and so the core will almost certainly saturate during this first half-cycle of voltage. During saturation, disproportionate amounts of mmf are needed to generate magnetic flux. This means that winding current, which creates the mmf to cause flux in the core, will disproportionately rise to a value easily exceeding twice its normal peak:


This is the mechanism causing inrush current in a transformer's primary winding when connected to an AC voltage source. As you can see, the magnitude of the inrush current strongly depends on the exact time that electrical connection to the source is made. If the transformer happens to have some residual magnetism in its core at the moment of connection to the source, the inrush could be even more severe. Because of this, transformer overcurrent protection devices are usually of the "slow-acting" variety, so as to tolerate current surges such as this without opening the circuit.

Surge Impedance Loading




The surge impedance loading or SIL of a transmission line is the MW loading of a transmission line at which a natural reactive power balance occurs.  
Transmission lines produce reactive power (Mvar) due to their natural capacitance. The amount of Mvar produced is dependent on the transmission line's capacitive reactance (XC) and the voltage (kV) at which the line is energized.  In equation form the Mvar produced is:  
                                                         
Transmission lines also utilize reactive power to support their magnetic fields (inductive).  The magnetic field strength is dependent on the magnitude of the current flow in the line and the line's natural inductive reactance (XL).  It follows then that the amount of Mvar used by a transmission line is a function of the current flow and inductive reactance.  In equation form the Mvar used by a transmission line is:
  
A transmission line's surge impedance loading or SIL is simply the MW loading (at a unity power factor) at which the line's Mvar usage is equal to the line's Mvar production.  In equation form we can state that the SIL occurs when:  

If we take the square root of both sides of the above equation and then substitute in the formulas for XL (=2pfL) and XC (=1/2pfC) we arrive at:  

The term     in the above equation is by definition the "surge impedance.  The theoretical
significance of the surge impedance is that if a purely resistive load that is equal to the surge impedance were connected to the end of a transmission line with no resistance, a voltage surge introduced to the sending end of the line would be absorbed completely at the receiving end.  The voltage at the receiving end would have the same magnitude as the sending end voltage and would have a phase angle that is lagging with respect to the sending end by an amount equal to the time required to travel across the line from sending to receiving end.

The value of the SIL to a system operator is realizing that when a line is loaded above its SIL it acts like a shunt reactor - absorbing Mvar from the system - and when a line is loaded below its SIL it acts like a shunt capacitor - supplying Mvar to the system.

Frequency



The primary reason for accurate frequency control is to allow the flow of alternating current power from multiple generators through the network to be controlled. The trend in system frequency is a measure of mismatch between demand and generation, and so is a necessary parameter for load control in interconnected systems.
Frequency of the system will vary as load and generation change. Increasing the mechanical input power to a synchronous generator will not greatly affect the system frequency but will produce more electric power from that unit. During a severe overload caused by tripping or failure of generators or transmission lines the power system frequency will decline, due to an imbalance of load versus generation. Loss of an interconnection, while exporting power (relative to system total generation) will cause system frequency to rise. Automatic generation control (AGC) is used to maintain scheduled frequency and interchange power flows. Control systems in power plants detect changes in the network-wide frequency and adjust mechanical power input to generators back to their target frequency. This counteracting usually takes a few tens of seconds due to the large rotating masses involved. Temporary frequency changes are an unavoidable consequence of changing demand. Exceptional or rapidly changing mains frequency is often a sign that an electricity distribution network is operating near its capacity limits, dramatic examples of which can sometimes be observed shortly before major outages.
Frequency protective relays on the power system network sense the decline of frequency and automatically initiate load shedding or tripping of interconnection lines, to preserve the operation of at least part of the network. Small frequency deviations (i.e.- 0.5 Hz on a 50 Hz or 60 Hz network) will result in automatic load shedding or other control actions to restore system frequency.
Smaller power systems, not extensively interconnected with many generators and loads, will not maintain frequency with the same degree of accuracy. Where system frequency is not tightly regulated during heavy load periods, the system operators may allow system frequency to rise during periods of light load, to maintain a daily average frequency of acceptable accuracy.

Frequency affects the power system in following ways;

 

Lighting


The first applications of commercial electric power were incandescent lighting  (normal bulb) and commutator-type electric motors. Both devices operate well on DC, but DC could not be easily changed in voltage, and was generally only produced at the required utilization voltage.
If an incandescent lamp is operated on a low-frequency current, the filament cools on each half-cycle of the alternating current, leading to perceptible change in brightness and flicker of the lamps.


Rotating machines


Commutator-type motors do not operate well on high-frequency AC because the rapid changes of current are opposed by the inductance of the motor field; even today, although commutator-type universal motors are common in 50 Hz and 60 Hz household appliances, they are small motors, less than 1 kW. The induction motor was found to work well on frequencies around 50 to 60 Hz but with the materials available in the 1890s would not work well at a frequency of, say, 133 Hz. There is a fixed relationship between the number of magnetic poles in the induction motor field, the frequency of the alternating current, and the rotation speed; so, a given standard speed limits the choice of frequency (and the reverse). Once AC electric motors became common, it was important to standardize frequency for compatibility with the customer's equipment.
Generators operated by slow-speed reciprocating engines will produce lower frequencies, for a given number of poles, than those operated by, for example, a high-speed steam turbine. For very slow prime mover speeds, it would be costly to build a generator with enough poles to provide a high AC frequency. As well, synchronizing two generators to the same speed was found to be easier at lower speeds. While belt drives were common as a way to increase speed of slow engines, in very large ratings (thousands of kilowatts) these were expensive, inefficient and unreliable.




Transmission and transformers


With AC, transformers can be used to step down high transmission voltages to lower customer utilization voltage. The transformer is effectively a voltage conversion device with no moving parts and requiring little maintenance. The use of AC eliminated the need for spinning DC voltage conversion motor-generators that require regular maintenance and monitoring.
Since, for a given power level, the dimensions of a transformer are roughly inversely proportional to frequency, a system with many transformers would be more economical at a higher frequency.
Electric power transmission over long lines favors lower frequencies. The effects of the distributed capacitance and inductance of the line are less at low frequency.

 

System interconnection


Generators can only be interconnected to operate in parallel if they are of the same frequency and wave-shape. By standardizing the frequency used, generators in a geographic area can be interconnected in a grid, providing reliability and cost savings.